Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Journal of Practical Stomatology ; (6): 317-320, 2016.
Article in Chinese | WPRIM | ID: wpr-490229

ABSTRACT

Objective:To compare the marginal and internal fit of selective laser melting(SLM)titanium crowns with lost-wax cast (LW)titanium crowns.Methods:Titanium crowns of 10 subjects were fabricated by SLM and conventional LW respectively(n =10).The marginal and internal gaps of the crowns were recorded with silicon film using a replica technique.Each silicon film was cut into 2 parts and the thickness of silicon layer was measured at ×100 magnification using a stereomicroscope,the data of marginal gap (MG)and internal gap(IG)were statistically analysed by ANOVA and SPSS statistical package version 17.0.Results:The MG (μm)of the titanium crowns of SLMgroup and LMgroup were 90.67 ±14.7 and 94.77 ±21.9(P 0.05),respectively.Conclusion:The marginal fit of the SLMcrowns is better than that of the LW ones,and is significantly smaller than 120 μm of the clinical generally accepted standards.

2.
Journal of Practical Stomatology ; (6): 313-317, 2015.
Article in Chinese | WPRIM | ID: wpr-463593

ABSTRACT

Objective:To compare the adaption of cobalt-chromium prostheses fabricated by selective laser melting(SLM)and conven-tional lost wax technique(LW)method.Methods:Cobalt-chromium crowns and three-unit fixed dental prostheses(FDPs)were fabrica-ted by selective laser melting(SLM)or by conventional lost wax technique(LW)respectively(n =5).Marginal fit and internal fit were examined using a light-body silicone.After setting,each silicon film was cut into 2 parts and the thickness of silicon layer was measured at 1 00 ×magnification using a digital microscope,the data of marginal gap(MG)and internal gap(IG)were statistically analysed by ANOVA and SPSS statistical package version 1 7.0.Results:The MG and IG(μm)of cobalt-chromium alloy crowns in EOS M270 group were 42.28 ±1 1 .58 and 1 25.75 ±47.67,in EOS M280 group 46.54 ±8.4 and 1 28.22 ±54.1 8,in LW group 48.66 ±1 2.08 and 1 35.37 ±46.89.The MG and IG(μm)of three-unit FDPs in EOS M270 group were 40.55 ±1 0.04 and 1 33.09 ±39.80,in EOS M280 group 45.36 ±1 0 and 1 38.94 ±50.61 ,in LW group 54.24 ±1 2.04 and 1 51 .87 ±61 .94(P <0.05),respectively.Conclu-sion:The marginal fit of the SLMgroup is superior to that of the LW group and significantly smaller than 1 20 μm of clinical generally accepted standards.SLMsystem can satisfy the clinical requirements.

SELECTION OF CITATIONS
SEARCH DETAIL